EtherNet/IP Connection
210
ZW User's Manual
READY
Ready
Turns OFF when the displacement sensor cannot execute control commands.
Turns ON when the displacement sensor can execute control commands.
RUN
Run screen
Turns ON when the displacement sensor is in the RUN mode.
Turns OFF when the displacement sensor is in the FUN mode.
ERR
Error
Turns ON when a displacement sensor error is detected.
Turns OFF when the displacement sensor is normal.
After it turns ON, it never turns OFF until the error clear signal (ERCLR signal) from the
user (Controller) turns ON.
BANKOUT1_A to
E
Current bank number This outputs the currently specified bank number.
It expresses the bank number in combinations of BANKOUTx_A to E.
(For details of combinations, see Reference.)
HOLDSTAT1
Hold execution status Turns ON when the displacement sensor is in the hold sampling period.
Turns OFF when the displacement sensor is outside the hold sampling period.
RESETSTAT1
Reset execution state Turns ON when the displacement sensor is in the reset execution state.
Turns OFF when the displacement sensor is in the reset non-execution state.
LIGHT1
Logical beam lighting
state
Turns ON when the logical beam is lit.
Turns OFF when the logical beam is out.
STABILITY1
Measurement
position
Turns ON when the measured value is in the measuring range.
Turns OFF when the measured value is outside the measuring range.
ENABLE1
Measurement state
Turns ON when the displacement sensor is ready for measurement.
Turns OFF when the displacement sensor cannot measure (excessive or insufficient
received light, outside measuring range, Calibration ROM not mounted, during FUN mode
non-measurement).
GATE1
Data output
completed
Turns ON when the displacement sensor completes control data output when hold is set.
The displacement sensor automatically turns OFF one Gate period after turning ON.
OR1
Overall judgment
result
Turns ON when even one of the judgment result of the displacement sensor TASK1 to 4 is
other than PASS.
Turns OFF when all of the judgment result of the displacement sensor TASK1 to 4 is
PASS.
HIGH1_T1-4
HIGH output
Turns ON when the judgment result of the displacement sensor TASK1 to 4 is HIGH
(HIGH threshold < measured value).
Turns OFF when the judgment result of the displacement sensor TASK1 to 4 is other than
HIGH.
PASS1_T1-4
PASS Output
Turns ON when the judgment result of the displacement sensor TASK1 to 4 is PASS (LOW
threshold
measured value
HIGH threshold).
Turns OFF when the judgment result of the displacement sensor TASK1 to 4 is other than
PASS.
LOW1_T1-4
LOW output
Turns ON when the judgment result of the displacement sensor TASK1 to 4 is LOW (LOW
threshold > measured value).
Turns OFF when the judgment result of the displacement sensor TASK1 to 4 is other than
LOW.
ZEROSTAT1_T1-4 Zero reset state
Turns ON when the displacement sensor TASK1 to 4 is in the zero reset execution state.
Turns OFF when the displacement sensor TASK1 to 4 is in the zero reset non-execution
state.
Command code
Command code
The executed command code is returned.
Response code
Response code
The response code of the executed command is stored.
Response data
Response data
The response data of the executed command is stored.
Signal
Signal name
Function
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......