Object Dictionary
ZW User's Manual
407
APPENDICES
10
• This object acquires the status of the displacement sensor.
Sub-index 18: ERR Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 19 to 33: Common Status Reserve Bit 17 to 31
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
3011 hex
Sensor Head 1 Status Flag
Sub-index 0: Number of entries
Setting range:
Unit:
Factory setting:
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Sensor Head 1 Status Flag
Setting range:
Unit:
Factory setting:
Size: 4 bytes (U32)
Access: RO
PDO map: T
Sub-index 2: HOLDSTAT 1 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 3: RESETSTAT 1 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 4: LIGHT 1 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 5: STABILITY 1 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 6: ENABLE 1 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 7: GATE 1 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 8: OR 1 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 9 to 17: Sensor Head 1 Status Reserve Bit 07 to 15
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Sub-index 18 to 21: ZEROSTAT 1_T1 to T4 Bit
Setting range: True (1) or False (0)
Unit:
Factory setting:
Size: 1 bit (BOOL)
Access: RO
PDO map: T
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......