Error Messages
ZW User's Manual
279
8
Tro
uble
s
hootin
g
Event name
RESET input error
Event code
7494 0000 Hex
Meaning
RESET input processing was not executed correctly.
Source
EtherCAT master function module
Source details
Slave
Detection
timing
When instructed
by the user
Error attributes
Level
Minor fault
Recovery
Error reset
(after
cancellation of
slave error)
Log category
System
Effects
User program
Continues
Operation
RESET input processing is not executed.
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
System-defined
variables
Variable
Data type
Name
None
Cause and
correction
Assumed cause
Correction
Prevention
RESETx input turned ON in the
FUN mode.
Switch to the RUN mode, and turn
RESETx input ON.
Attached
information
None
Precautions/
Remarks
None
Event name
ZERO input error
Event code
7495 0000 Hex
Meaning
ZERO input processing was not executed correctly.
Source
EtherCAT master function module
Source details
Slave
Detection
timing
When instructed
by the user
Error attributes
Level
Minor fault
Recovery
Error reset
(after
cancellation of
slave error)
Log category
System
Effects
User program
Continues
Operation
ZERO input processing is not executed.
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
System-defined
variables
Variable
Data type
Name
None
Cause and
correction
Assumed cause
Correction
Prevention
ZEROx input turned ON in the FUN
mode.
Switch to the RUN mode, and turn
ZEROx input ON.
ZEROx input turned ON in a non-
measurement state.
Modify the program so that ZEROx
input turns ON when the sensor is
ready for measurement.
Program so that ZEROx input turns
ON when the sensor is ready for
measurement.
ZEROx input turned ON for a task
whose status is OFF.
Modify the program so that the task
that turns ZEROx input ON turns
the status ON.
Program so that the task that turns
ZEROx input ON turns the status
ON.
Attached
information
None
Precautions/
Remarks
None
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......