EtherNet/IP Connection
206
ZW User's Manual
●
Settings in the ZW (Device Parameter Settings)
* The packet interval (RPI) is set in the connection settings between the PLC and the Sensor. No setting is required here.
1
Right-click the ZW in the network on the Network Configurator and select [Parameter] - [Edit].
2
The Edit Device Parameters Dialog Box will be displayed. Make the required settings.
Parameter name
Value
Setting range
001 Input Size
The total size of response area and output area
56
002 Output Size
The data size of command area
24
003 RPI
*
The requested packet interval
10000