Setting Threshold Value
ZW User's Manual
69
3
Basic Operation
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Task Settings] icon (
)
Task settings window : [Judgment]
• Hysteresis (hysteresis width) can also be set to threshold values. Set hysteresis when measured values are
dispersed around a threshold value, and judgments are unstable, to prevent chattering.
Setting Operation at Judgment Output p.146
• Threshold values can also be adjusted by directly entering values in the RUN mode.
This helps you to make fine adjustments without shutting down the system.
Changing Threshold Values p.301
Item
Setting item
Setting value
Description
Judgment
LOW threshold
- 999.999999 to 0 (default value) to
999.999999 [mm]
Set the lower limit (LOW) threshold value.
HIGH threshold
- 999.999999 to 0 (default value) to
999.999999 [mm]
Set the upper limit (HIGH) threshold value.
1
Enter the [LOW threshold] and [HIGH thresh-
old].
Threshold Value Settings can also be set by the operating keys on the Sensor Controller.
9-10 Setting Threshold Value p.331
Important
Note
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......