Specifications and External Dimensions
358
ZW User's Manual
10-1 Specifications and External Dimensions
Sensor Head
Specifications
*1:
Capacity value when OMRON standard mirror surface target is measured at the measurement center distance as the average of 4,096
times
When connected with the controller for the Export Control Trade Ordinance (ZW-CE1
@
T/ZW-C1
@@
T), the minimum resolution is 0.25
m,
regardless of the Sensor Head and the number of measurements averaged.
*2:
Material setting for the OMRON standard mirror surface target: Error from an ideal straight line when measuring on mirror surface
The reference values for linearity when targets to measure other than the above are as in the table below.
*3:
Capacity value defined by 1/e2 (13.5%) of the center optical intensity in the measured area
*4:
Temperature characteristic at the measurement center distance when fastened with an aluminum jig between the Sensor Head and the
target and the Sensor Head and the Sensor Controller are set in the same temperature environment. Figures in parentheses are converted
value obtained by subtracting the effect of expansion and contraction of the aluminum jig itself.
Item
Specifications
ZW-S07
ZW-S20
ZW-S30
ZW-S40
ZW-SR07
ZW-SR20
ZW-SR40
Measurement center distance
7 mm
20 mm
30 mm
40 mm
7 mm
20 mm
40 mm
Measuring range
±0.3 mm
±1 mm
±3 mm
±6 mm
±0.3 mm
±1 mm
±6 mm
Static resolution
*1
0.01
m
0.02
m
0.06
m
0.08
m
0.01
m
0.02
m
0.08
m
Linearity
*2
±0.8
m
±1.2
m
±4.5
m
±7.0
m
±1.1
m
±1.6
m
±9.3
m
Spot diameter
*3
Near
20
m dia.
45
m dia.
70
m dia.
90
m dia.
20
m dia.
45
m dia.
90
m dia.
Center
18
m dia.
40
m dia.
60
m dia.
80
m dia.
18
m dia.
40
m dia.
80
m dia.
Far
20
m dia.
45
m dia.
70
m dia.
90
m dia.
20
m dia.
45
m dia.
90
m dia.
Measuring cycle
500
s to 10 ms
Operating ambient illumination
Illumination on object surface of 10000 lx or less (incandescent light)
Ambient temperature range
Operation: 0 to +50
C, Storage: -15 to +60
C
(No freezing and condensation)
Ambient humidity range
Operation/storage: 35 or 85% (No condensation)
Degree of protection
IP40 (IEC60529)
Vibration resistance (destructive)
10 to 150 Hz (half amplitude 0.35 mm), 80 mins in each of X/Y/Z directions
Shock resistance (destructive)
150 m/s
2
, 6 direction, 3 times each (up/down, left/right, forward/backward)
Temperature characteristic
*4
0.6
m/
C
(0.45
m/
C)
1.5
m/
C
(1.0
m/
C)
2.8
m/
C
(2.0
m/
C)
4.8
m/
C
(3.8
m/
C)
0.6
m/
C
(0.45
m/
C)
1.5
m/
C
(1.0
m/
C)
4.8
m/
C
(3.8
m/
C)
Material
Chassis: aluminum die cast
Fiber cable sheath: PVC
Calibration ROM: PC
Fiber cable length
0.3 m, 2 m (flex-resistant cable)
Fiber cable minimum bend radius
20 mm
Insulation resistance (Calibration
ROM)
Between case and all terminals: 20 M
(by 250 V megger)
Dielectric strength (Calibration
ROM)
Between case and all terminals: 1000 VAC, 50/60 Hz, 1 min
Weight
Approx. 105 g (chassis, fiber cable total)
Approx. 130 g (chassis, fiber cable total)
Accessories
Instruction Manual, Calibration ROM fixing screws (M2), Note on Use
Target to Measure
ZW-S07
ZW-S20
ZW-S30
ZW-S40
ZW-SR07
ZW-SR20
ZW-SR40
Glass
±1.0
m
±1.2
m
±4.5
m
±7.0
m
±1.1
m
±1.6
m
±9.3
m
SUS BA
±1.2
m
±1.4
m
±5.5
m
±8.5
m
±1.2
m
±1.8
m
±9.3
m
White ceramic
±1.6
m
±1.7
m
±6.4
m
±9.5
m
±1.6
m
±1.9
m
±11.0
m
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......