Wiring
ZW User's Manual
2
Install
a
tion an
d
C
onn
ecti
ons
45
Class
Name
Description
Parallel
output
HIGH output
This outputs judgment results - HIGH (HIGH threshold values < Measured value).
PASS output
This outputs judgment results - PASS (LOW threshold values
Measured value
HIGH
threshold values).
LOW output
This outputs judgment results - LOW (LOW threshold values > Measured value).
ALARM output
This turns ON when there is a system error.
BUSY output
This turns ON during sampling with the hold function enabled. It allows you to check
whether or not the self-trigger is functioning correctly.
It also turns ON during bank switching.
ENABLE output
This turns ON when the sensor is ready for measurement.
This output is interlocked with the ENABLE indicator.
BANK_OUT output
This outputs the currently specified bank number.
It expresses the bank number in combinations of BANK_OUT1, 2 and 3.
Parallel
input
ZERO input
This is used to execute and clear a zero reset.
RESET input
This resets all executing measurements and outputs.
While a RESET is being input, judgment output conforms to the non-measurement setting.
If this RESET input switches ON while the hold function is used, the state in effect before
the hold function was set will be restored.
TIMING input
This is a signal input from an external device that is used to time the hold function with the
continuous measurement function enabled.
This is a signal input from an external device that is used to time the measurement with the
trigger measurement function enabled.
LED OFF input
This LED-OFF signal puts out the measurement LED.
While LED-OFF is being input, the analog output, binary output, and judgment output
conform to the non-measurement setting.
BANK_SEL input
This is used for switching banks.
Specify the bank number in combinations of BANK_SEL1, 2 and 3.
However, if the bank mode is set to "JUDGEMENT", the bank cannot be switched at the
external signal input because the number of banks increases to 32.
LOGGING input
This is used to start and end internal logging.
Bank Number BANK_OUT1
BANK_OUT2
BANK_OUT3
BANK1
OFF
OFF
OFF
BANK2
ON
OFF
OFF
BANK3
OFF
ON
OFF
BANK4
ON
ON
OFF
BANK5
OFF
OFF
ON
BANK6
ON
OFF
ON
BANK7
OFF
ON
ON
BANK8
ON
ON
ON
Bank Number BANK_SEL1
BANK_SEL2
BANK_SEL3
BANK1
OFF
OFF
OFF
BANK2
ON
OFF
OFF
BANK3
OFF
ON
OFF
BANK4
ON
ON
OFF
BANK5
OFF
OFF
ON
BANK6
ON
OFF
ON
BANK7
OFF
ON
ON
BANK8
ON
ON
ON
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......