ZW User's Manual
5
• If there is no PC, or specifically there is no SG (0 V)/FG short-circuiting path, grounding the Sensor
Controller's frame ground terminal will not cause seizure. Wire the PLC after checking the specification of
your PLC.
• The dedicated RS-232C cable (ZW-XRS2/XPT2) has its cable shield isolated from the connector housing.
[(3)]
4. Regulations and Standards
• EN61326-1
• Electromagnetic environment : Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
• The following condition is applied to the immunity test of this product.
: There may be cases that current or voltage output fluctuate within ± 3%F.S. when a sensor is experienced
electromagnetic interference.
• Notice for Korea Radio Law
A급 기기 (업무용 방송통신기자재)
이 기기는 업무용 ( A급 ) 전자파적합기기로서 판매자
또는 사용자는 이 점을 주의하시기 바라며 , 가정외의
지역에서 사용하는 것을 목적으로 합니다.
5. Others
• Do not use this product for nuclear facilities, or safety circuits involving human lives.
• Do not attempt to disassemble, repair, modify, apply pressure to deform or burn up the body.
• Dispose of this product as industrial waste.
• Use exclusive devices, including a sensor head, Calibration ROM, fiber cable or RS-232C cable, to connect,
or ignition, burst, false operation or breakdown may be caused.
• Do not cut fiber cable. Glass at the cut section may cause injury. Also, if cut, it will not work normally
anymore.
• Whenever any trouble, including, strange odor smelled, the body overheated or smoke escaped, was found,
immediately stop the operation, and consult an OMRON branch or sales office with the system shut down.
• Do not drop or make a strong impact on the unit.
• Before using any equipment provided with a lock mechanism, make sure that it has been locked.
24V
FG
SG
FG
SG
FG
SG
FG
SG
SG
24 V DC
power
supply
Sensor Controller
24V
PC or PLC
SG: Signal Ground (0 V for 24 V DC power supply)
FG: Frame Ground
FG
(1)
(2)
SG
FG
SG
FG
SG
SG
Power supply
circuit
(3)
RS-232C
connector housing
RS-232C
Ethernet
connector housing
Ethernet
SG
FG
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......