Parallel I/O connection
152
ZW User's Manual
Timing Chart
The following shows the timing charts when communication is performed with external devices.
Basic operation
Explanation of operations
(1) During each measuring cycle, the LEDs are lit and exposure is started.
(2) After the end of exposure, measurement starts.
(3) After the end of measurement, the judgment result is output.
(4) After the judgment result output, the analog output is updated.
Item
Min.
Max.
T0
Measuring cycle
0.5ms
Depends on the set conditions
(0.5 to 10.0 ms)
T1
Exposure time
1
s
Max. exposure time
(1 to 5000
s)
T2
Response time of output
T0x2
T0x2
T3
Response time of analog output
0.1 ms
(2)
(3)
J
u
dgment o
u
tp
u
t
HIGH/PASS/LO
W
)
Analog o
u
tp
u
t
(4)
Expos
u
re
T0
(1)
T1
T2
T3
O
N
OFF