NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 390 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
RTC Initiation Register (RTC_INIT)
Register
Offset
R/W
Description
Reset Value
RTC_INIT
0x000
R/W
RTC Initiation Register
0x0000_0000
31
30
29
28
27
26
25
24
INIT
23
22
21
20
19
18
17
16
INIT
15
14
13
12
11
10
9
8
INIT
7
6
5
4
3
2
1
0
INIT
INIT/Active
Bits
Description
[31:1]
INIT
RTC Initiation
After RTC block is powered on, RTC is at reset state. User has to write a number (0x
a5eb1357) to INIT to make RTC leaving reset state. Once the INIT is written as
0xa5eb1357, the RTC will be in un-reset state permanently.
The INIT is a write-
only field and read value will be always “0”.
[0]
INIT/Active
RTC Active Status (Read Only)
0 = RTC is at reset state.
1 = RTC is at normal active state.