NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 451 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
0100 = 30/14 (High-speed/Normal Speed) Trigger Level (Bytes).
0101 = 46/14 (High-speed/Normal Speed) Trigger Level (Bytes).
0110 = 62/14 (High-speed/Normal Speed) Trigger Level (Bytes).
others = 62/14 (High-speed/Normal Speed) Trigger Level (Bytes).
[3]
Reserved
Reserved.
[2]
TFR
TX Field Software Reset
When TFR(UA_FCR[2]) is set, all the byte in the transmit FIFO and TX internal state
machine are cleared.
0 = No effect.
1 = Reset the TX internal state machine and pointers.
Note:
This bit will auto clear needs at least 3 UART engine clock cycles.
[1]
RFR
RX Field Software Reset
When RFR(UA_FCR[1]) is set, all the byte in the receiver FIFO and RX internal state
machine are cleared.
0 = No effect.
1 = Reset the RX internal state machine and pointers.
Note:
This bit will be automatically cleared for at least 3 UART engine clock cycles.
[0]
Reserved