NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 1210 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
ADC Configure (ADC_CONF)
Register
Offset
R/W
Description
Reset Value
ADC_CONF
0x04
R/W
ADC Configure
0x0000_0000
Bits
Description
[31:24]
ADCSAMPCNT
ADC Sample Counter
Set the counter value to extend the ADC start signal period to get more sampling
time for precise conversion.
[22]
HSPEED
High Speed Enable
Enable ADC to high speed mode.
[21]
DISZMAVEN
Display Z Mean Average Enable
Pressure Mean average for Z1 and Z2 function enable.
[20]
DISTMAVEN
Display T Mean Average Enable
Touch Mean average for X and Y function enable.
31
30
29
28
27
26
25
24
ADCSAMPCNT
23
22
21
20
19
18
17
16
Reserved
HSPEED
DISZMAVEN DISTMAVEN
REFCNT
15
14
13
12
11
10
9
8
Reserved
SELFT_EN
KPC_EN
VBAT_EN
7
6
5
4
3
2
1
0
REFSEL
CHSEL
NAC_EN
Z_EN
T_EN