NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 1053 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
[3]
EY422
Encode Image Format
0 = YUV 4:2:0.
1 = YUV 4:2:2.
[2]
QT_BUSY
Quantization-table Busy Status (Read-only)
0 = Quantization-Table is ready for host access.
1 = Quantization-
Table is busy and can’t be accessed.
[1]
ENG_RST
Soft Reset JPEG Engine (Except JPEG Control Registers)
0 = Disable. Normal operation
1 = Reset JPEG engine, but the value of control registers keep no change.
[0]
JPG_EN
JPEG Engine Operation Control
0 = Disable.
1 = Enable.