8 - 11
8. GENERAL GAIN ADJUSTMENT
8.5 Differences in auto tuning between MELSERVO-J2 and MELSERVO-J2-Super
8.5.1 Response level setting
To meet higher response demands, the MELSERVO-J2-Super series has been changed in response level
setting range from the MELSERVO-J2 series. The following table lists comparison of the response level
setting.
Response level setting
Parameter No. 3
MELSERVO-J2 series
MELSERVO-J2-Super series
Response level setting
Machine resonance frequency
Response level setting
Machine resonance frequency guideline
1 15Hz
1 20Hz 2
20Hz
3 25Hz
4 30Hz
5 35Hz
2 40Hz 6
45Hz
7 55Hz
3 60Hz 8
70Hz
4 80Hz 9
85Hz
5 100Hz A
105Hz
B 130Hz
C 160Hz
D 200Hz
E 240Hz
F 300Hz
Note that because of a slight difference in gain adjustment pattern, response may not be the same if the
resonance frequency is set to the same value.
8.5.2 Auto tuning selection
The MELSERVO-J2-Super series has an addition of the load inertia moment ratio fixing mode. It also has
the addition of the manual mode 1 which permits manual adjustment with three parameters.
Parameter No. 3
Auto tuning selection
Auto tuning selection
Gain adjustment mode
MELSERVO-J2 series
MELSERVO-J2-Super series
Remarks
Interpolation mode
0
0
Position control gain 1 is fixed.
Auto tuning mode 1
1
1
Ordinary auto tuning
Auto tuning
Auto tuning mode 2
2
Estimation of load inertia moment
ratio stopped.
Response level setting valid.
Manual mode 1
3
Simple manual adjustment
Auto tuning
invalid
Manual mode 2
2
4
Manual adjustment of all gains
Summary of Contents for MR-J2S-10CP
Page 11: ...A 10 MEMO ...
Page 19: ...8 MEMO ...
Page 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Page 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Page 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Page 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 231: ...10 2 10 INSPECTION MEMO ...
Page 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Page 257: ...13 8 13 CHARACTERISTICS MEMO ...