7 - 16
7. DISPLAY AND OPERATION
7.6.2 Operation example
(1) Parameter of 5 or less digits
The following example shows the operation procedure performed after power-on to change the home
position setting method (Parameter No.8) into the data setting type. Press "
MODE
" to switch to the
basic parameter screen.
Press
four times. Select parameter No.8 with UP
DOWN.
or
MODE
The parameter number is displayed.
UP
DOWN
or
Press
to change the number.
SET
Press
twice.
The set value of the specified parameter number flickers.
UP
Press
twice.
During flickering, the set value can be changed.
UP
DOWN
or
Use
.
SET
Press
to enter.
( 2: Data setting type)
To shift to the next parameter, press the "
UP
" or "
DOWN
" button.
When changing the parameter No.8 (home position return type) setting, change its set value, then
switch power off once and switch it on again to make the new value valid.