14 - 16
14. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
(Note 3)
Power
supply
NFB
MC
Servo amplifier
L
11
L
21
L
1
L
2
L
3
Power regeneration
converter FR-RC
SK
ON
MC
B C
N
P
C
RDY
SE
Alarm
output
RDY
output
A
B
C
5m(16.4ft) or less
N/
P/
Operation ready
MC
OFF
EMG
RA2
FR-RC
Ready
Power factor improving reactor
FR-BAL
(Note 2)
Phase detection
terminals
B
C
R/L
1
S/L
2
T/L
3
RX
R
SX
S
TX
T
(Note 1)
ALM
COM
VDD
RA2
EMG
SON
SG
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the
FR-RC will not operate.
2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected to P terminal
and C terminal.
3. Refer to section 1.2 for the power supply specification.