4 - 24
4. OPERATION
4.3.2 Manual pulse generator operation
(1) Setting
Set the input signal and parameters as follows according to the purpose of use. In this case, the point
table No. selection 1 to 5 (DI0 to DI4) are invalid.
Item Setting
method Description
Manual operation mode selection
Automatic/manual selection (MD0)
Open MD0-SG (OFF).
Manual pulse generator
multiplication
Parameter No.1
Set the multiplication ratio of servo
motor rotation to the pulses generated by
the manual pulse generator.
For more information, refer to (3) of this
section.
Servo motor rotation direction
Parameter No.1
Refer to (2) of this section.
(2) Servo motor rotation direction
Servo motor rotation direction
Parameter No. 1 setting
Manual pulse generator: forward rotation
Manual pulse generator: reverse rotation
0
CCW rotation
CW rotation
1
CW rotation
CCW rotation
Forward rotation
CCW
CW
(3) Manual pulse generator multiplication
(a) Using the parameter for setting
Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No. 1 setting
Multiplication ratio of servo motor rotation to manual
pulse generator rotation
Moving distance
0
1
time
1[ m]
1
10
times
10[ m]
2
100
times
100[ m]
Summary of Contents for MR-J2S-10CP
Page 11: ...A 10 MEMO ...
Page 19: ...8 MEMO ...
Page 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Page 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Page 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Page 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 231: ...10 2 10 INSPECTION MEMO ...
Page 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Page 257: ...13 8 13 CHARACTERISTICS MEMO ...