4 - 17
4. OPERATION
2) Positioning that reverses the direction midway
The position data (addresses) of the midway point tables are used for positioning and the
direction is reversed to reach the positioning address set in the last point table.
The operation example given below assumes that the set values are as indicated in the following
table.
Point table
No.
Position data
[ 10
STM
m]
Servo motor
speed [r/min]
Acceleration time constant
[ms]
Deceleration time constant
[ms]
Dwell [ms]
(Note 1)
Auxiliary
function
1 10.00 3000
100
150
0 1
2 5.00 2000
Invalid
Invalid
0
0
(Note 2)
Note 1. Always set "0".
2. Always set "0" to the auxiliary function of the last point table among the consecutive point tables.
ON
OFF
0
0
5.00
10.00
1
1
Deceleration time constant
of point table No. 1 (150)
Acceleration time constant
of point table No. 1 (100)
Position address
Selected point table No.
Servo motor speed
Forward rotation start
(ST1)
Forward
rotation
Reverse
rotation
Speed
(2000)
Speed
(3000)
Point No. out put
(PT0 to PT4)
Summary of Contents for MR-J2S-10CP
Page 11: ...A 10 MEMO ...
Page 19: ...8 MEMO ...
Page 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Page 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Page 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Page 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 231: ...10 2 10 INSPECTION MEMO ...
Page 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Page 257: ...13 8 13 CHARACTERISTICS MEMO ...