11 - 7
11. TROUBLESHOOTING
Display Name
Definition
Cause
Action
1. Servo amplifier fault caused the
parameter setting to be rewritten.
Change the servo amplifier.
2. Regenerative option not used with
servo amplifier was selected in
parameter No.0.
Set parameter No.0 correctly.
3. Value outside setting range has
been set in some parameter.
Set the parameter correctly.
4. Value outside setting range has
been set in electronic gear.
Set parameters No. 4, 5 correctly.
5. Opposite sign has been set in
software limit increasing side
(parameters No. 46, 47). Similarly,
opposite sign has been set in
software limit decreasing side
(parameters No. 48, 49).
Set parameters No. 46 to 49 correctly.
6. Opposite sign has been set in
position range output address
increasing side (parameters No. 50,
51). Similarly, opposite sign has
been set in position range output
address decreasing side
(parameters No. 52, 53).
Set parameters No. 50 to 53 correctly.
AL.37 Parameter
error
Parameter setting is
wrong.
7. The number of write times to EEP-
ROM exceeded 100,000 due to
parameter write, program write,
etc.
Change the servo amplifier.
1. Servo amplifier faulty.
Change the servo amplifier.
2. The power supply was turned on
and off continuously by overloaded
status.
The drive method is reviewed.
AL.45 Main
circuit
device overheat
Main circuit device
overheat
3. Air cooling fan of servo amplifier
stops.
1. Exchange the cooling fan or the servo
amplifier.
2. Reduce ambient temperature.
1. Ambient temperature of servo
motor is over 40 (104 ).
Review environment so that ambient
temperature is 0 to 40 (32 to 104 ).
2. Servo motor is overloaded.
1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger
output.
AL.46 Servo
motor
overheat
Servo motor
temperature rise
actuated the
thermal sensor.
3. Thermal sensor in encoder is faulty. Change servo motor.
1. Servo amplifier is used in excess of
its continuous output current.
1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger
output.
2. Servo system is instable and
hunting.
1. Repeat acceleration/
deceleration to execute auto tuning.
2. Change auto tuning response setting.
3. Set auto tuning to OFF and make gain
adjustment manually.
3. Machine struck something.
1. Review operation pattern.
2. Install limit switches.
4. Wrong connection of servo motor.
Servo amplifier's output terminals
U, V, W do not match servo motor's
input terminals U, V, W.
Connect correctly.
AL.50 Overload
1
Load
exceeded
overload protection
characteristic of
servo amplifier.
5. Encoder faulty.
Checking method
When the servo motor shaft is
rotated with the servo off, the
cumulative feedback pulses do
not vary in proportion to the
rotary angle of the shaft but the
indication skips or returns midway.
Change the servo motor.
Summary of Contents for MR-J2S-10CP
Page 11: ...A 10 MEMO ...
Page 19: ...8 MEMO ...
Page 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Page 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Page 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Page 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 231: ...10 2 10 INSPECTION MEMO ...
Page 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Page 257: ...13 8 13 CHARACTERISTICS MEMO ...