6.7 Test operation
CAUTION
When confirming the machine operation in the test operation mode, use the
machine after checking that the safety mechanism such as the forced stop (EMG)
operates.
If any operational fault has occurred, stop operation using the forced stop (EMG).
6.7.1 Jog operation
POINT
For the program operation, refer to the manual of MR Configurator.
The servo motor will not operate if the forced stop (EMG), forward
rotation stroke end (LSP) and reverse rotation stroke end (LSN) are off.
Make automatic ON setting to turn on these devices or make device
setting to assign them as external input signals and turn ON across these
signals and SG. (Refer to section 6.6.)
When an alarm occurs, the JOG operation is automatically canceled.
Hold down the “
Forward
” or “
Reverse
” button to rotate the servo motor. Release the “
Forward
” or
“
Reverse
” button to stop.
Click “
Test
” on the menu bar and choose “
Jog
” on the menu.
When the above choices are made, the following window appears.