15 - 30
15. COMMUNICATION FUNCTIONS
15.12.9 Output signal pin ON/OFF output signal (DO) forced output
In the test operation mode, the output signal pins can be turned on/off independently of the servo status.
Using command [9][0], disable the output signals in advance.
(1) Choosing DO forced output in test operation mode
Transmit command [8][B] data No. [0][0] data "0004" to choose DO forced output.
0 0
Selection of test operation mode
4: DO forced output (output signal forced output)
0 4
(2) External output signal ON/OFF
Transmit the following communication commands.
Command Data No.
Setting data
[9][2] [A][0] See
below.
Command of each bit is sent to the slave station in hexadecimal.
b31
b0
0: OFF
1: ON
b1
bit
External output pin bit
External output pin bit
External output pin bit
External output pin
0 CN1A-19
8
16 24
1 CN1A-18
9
17 25
2 CN1B-19
10
18 26
3 CN1B-6
11
19 27
4 CN1B-4
12
20 28
5 CN1B-18
13
21 29
6 CN1A-14
14
22 30
7
15 23 31