4 - 22
4. OPERATION
4.3 Manual operation mode
For machine adjustment, home position matching, etc., jog operation or a manual pulse generator may be
used to make a motion to any position.
4.3.1 Jog operation
(1) Setting
Set the input signal and parameters as follows according to the purpose of use. In this case, the point
table No. selection 1 to 5 (DI0 to DI4) are invalid.
Item Setting
method
Description
Manual operation mode selection
Automatic/manual selection (MD0)
Open MD0-SG (OFF).
Servo motor rotation direction
Parameter No.1
Refer to (2) of this section.
Jog speed
Parameter No.13
Set the speed of the servo motor.
Acceleration/deceleration time constant
Point table No.1
Use the acceleration/deceleration
time constants in point table No.1.
(2) Servo motor rotation direction
Servo motor rotation direction
Parameter No. 1 setting
Forward rotation start (ST1) ON
Reverse rotation start (ST2) ON
0
CCW rotation
CW rotation
1
CW rotation
CCW rotation
ST1:ON
CCW
CW
ST2:ON
ST2:ON
CCW
CW
ST1:ON
Parameter No. 1
0
Parameter No. 1
1
(3) Operation
By shorting ST1-SG, operation is performed under the conditions of the jog speed set in the parameter
and the acceleration and deceleration time constants in set point table No.1. For the rotation direction,
refer to (2) of this section. By shorting ST2-SG, the servo motor rotates in the reverse direction to
forward rotation start (ST1).
Summary of Contents for MR-J2S-10CP
Page 11: ...A 10 MEMO ...
Page 19: ...8 MEMO ...
Page 45: ...1 26 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 181: ...6 20 6 MR Configurator SERVO CONFIGURATION SOFTWARE MEMO ...
Page 207: ...7 26 7 DISPLAY AND OPERATION MEMO ...
Page 219: ...8 12 8 GENERAL GAIN ADJUSTMENT MEMO ...
Page 229: ...9 10 9 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 231: ...10 2 10 INSPECTION MEMO ...
Page 249: ...12 8 12 OUTLINE DIMENSION DRAWINGS MEMO ...
Page 257: ...13 8 13 CHARACTERISTICS MEMO ...