Initial Setup
Symptom
Possible Cause
Corrective Action
The system is generating
“Warning” license violation
messages in maintenance
logs and the ESM System
Administration Tool (pop-
ups and banner status
messages).
One of the following
warning-level license
violation events has
occurred:
•
Over Allocation
•
Missing DLM
•
Missing Application
Group Member
•
Core Package capability
exceeded
•
License Keys cannot be
validated
•
System ID mismatch
•
SDS is off
•
Duplicate System
•
Multiple DLMs
•
Failure of timely
synchronization with
AMC
•
Application Group is in
license violation mode
•
“licensekeys” or
“licensecert” file is
corrupt or has been
tampered with
Correct the license
violation event.
The system is generating
“Minor” license violation
messages in maintenance
logs, alarms, and the ESM
interface (pop-ups on
multiple forms and banner
status messages).
The “Warning” level license
violation escalation timer
has expired (2 days after
the original event).
Correct the license
violation event.
Document Version 1.0