Tools and Embedded Applications
Symptom
Probable Cause
Corrective Action
“Phantom” ringing occurs
when an ACD Hot Desk
Agent is logged into an
ACD.
The user profile for a hot
desk agent supports up to
47 programmable keys.
If an agent is assigned
47 feature keys and then
logs into an ACD hot desk
set that has fewer than
47 programmable keys
on it, the extra keys are
not accessible. If one of
these “inaccessible” keys
is programmed as a line
appearance, calls for the
line appearance will still
ring at the phone.
To avoid this problem,
choose one device
type that supports 13
programmable keys,
program a consistent
layout for the buttons, and
provide printed button
templates for each ACD
hot desk set.
Unable to log in to a 5560
IPT. Set display shows
“Login failed due to an
invalid dn”.
DNs for both the HDU
and the 5560 IPT are on
different ICPs/MiVoice
Business systems.
If the 5560 IPT is resilient,
the 5560 IPT and the hot
desk user DN must have
the same primary and
secondary.
Re-assign DNs so that the
5560 and HUD are on the
same system(s).
Device behaving incorrectly
after logging in with a 5560
IPT user profile. Display
continues to show previous
hot desk login and keys.
Attempts to log in again
results in “Login failed due
to a system error”
The device is NOT a 5560
IPT. Users of a 5560 IPT
can only hot desk into
another 5560 IPT.
Reboot the device to
restore in to normal
operation.
Document Version 1.0
207
Troubleshooting Guide
Summary of Contents for MiVoice Business 3300 ICP
Page 1: ...MiVoice Business Troubleshooting Guide Release 9 4 SP1 Document Version 1 0 June 2022 ...
Page 10: ...Introduction Document Version 1 0 Troubleshooting Guide 4 ...
Page 45: ...Figure 4 DNS setting on MSL server manager ...
Page 323: ...Diagnosing Problems Document Version 1 0 317 Troubleshooting Guide ...