Diagnosing Problems
Symptom
Commands
Description
Call problems
are generating
message output
that you need to
capture in a file for
interpretation
edt enable logtofile
(turns on message
tracing)
edt disable logtofile
(turns off message
tracing)
This command puts all of the traces
turned on by “edt trace …” into the “/db/
LDS_Trace.rtf” file (DigTrkTrace prior to
3300 Rls 6.1).
If you need to enable tracing on a busy
switch, you should send the output to the
trace file because the output to the
response window is slow and can impact
the performance of the 3300 ICP
This log file must be interpreted by Mitel
designers. It is not meant to be interpreted
by customers or field technicians.
T1/E1 module
(embedded PRI)
issues
All ESM digital
trunk maintenance
commands
available to the
NSU apply to the
T1/E1 module
and can be
entered through
the Maintenance
commands form
of the System
Administration Tool.
Refer to Mitel Knowledge Base article
04-5191-00014
10.11 Hardware
Using LEDs to Diagnose Faults
Controllers, units, modules and cards have light-emitting diodes (LEDs) that indicate their
current status. Refer to the Technician's Handbook for tables that list the LED states and
the meaning of each state.
•
on page 316
•
Diagnosing DSP Module Related Issues
on page 318
Document Version 1.0
315
Troubleshooting Guide
Summary of Contents for MiVoice Business 3300 ICP
Page 1: ...MiVoice Business Troubleshooting Guide Release 9 4 SP1 Document Version 1 0 June 2022 ...
Page 10: ...Introduction Document Version 1 0 Troubleshooting Guide 4 ...
Page 45: ...Figure 4 DNS setting on MSL server manager ...
Page 323: ...Diagnosing Problems Document Version 1 0 317 Troubleshooting Guide ...