Symptom
Commands
Description
Link alarms - Part 1
(System unable
to seize trunks
or trunks are
unavailable,
network
synchronization
issues, and so
forth)
edt show framer
stats all
edt show framer
regs all
Outputs the statistical registers of the
framers and the register settings. The
outputs show exact the physical issue that
is affecting the framer. You may have to
dump
the “framer stats” more than once as
these registers change over time. Collect
this
output in association with the output from
the “dtstats read”, “net state” and “show
faults digital links” maintenance
commands.
Note
:
The output from these commands
must be interpreted by Mitel Software
Design.
Link alarms - Part 2
(Trunks not in idle
when there are no
calls up)
edt show vdsu
alarms <plid>
edt show vdsu
channel <plid>
Shows the current digital trunking alarms
and channel status. Use this command in
conjunction with “dtstats read” and “state”
commands.
Note
:
The output from these commands
may need to be interpreted by Mitel
Software Design.