A-2
Specifications
Switch Fabric
•
Full digital, nonblocking
Electrical
Specifications
•
45 Watts (154 BTUs/hr.) per ACS processor module during normal power consumption
•
85 Watts (290 BTUs/hr.) per ACS processor module during maximum power consumption
•
10 Watts (35 BTUs/hr.) per 400 module, normal and maximum power consumption
•
35 Watts (120 BTUs/hr.) per 206 module during normal power consumption
•
75 Watts (256 BTUs/hr.) per 206 module during maximum power consumption
•
U.S., Canada, and other 110V countries:
−
ACS processor module and one 206 module (2-Slot carrier) = 2.3 Amps max. current,
full system capacity
−
ACS processor module and four 206 modules (5-Slot carrier) = 4 Amps max. current, full
system capacity
•
Countries using 220 V:
−
ACS processor module and one 206 module (2-Slot carrier) = 1.2 Amps max. current,
full system capacity
−
ACS processor module and four 206 modules (5-Slot carrier) = 2 Amps max. current, full
system capacity
•
45 days to 6 months memory backup with 2 AAA-size standard alkaline batteries (IEC LR03)
Processor Module
Specifications
•
68306 16 Mhz processor
•
256Kbyte RAM
•
512Kbyte FLASH ROM
•
Custom VLSI DSP ASIC—16 bit, 52 Mhz
−
VLSI = Very Large Scale Integration
−
DSP = Digital Signal Processor
−
ASIC = Application Specific Integrated Circuit
Extension Jack
Specifications
•
Ringing voltage: +5VDC, –140 VDC peak to peak; trapezoidal wave shaping
•
35- to 38-Volt talk battery
•
Ringing frequency: 20 Hz
PAGE Jack
Specifications
•
Draws current on inner wire pair
•
Provides paging contact closure on outer wire pair
•
600 Ohm impedance
MUSIC ON
HOLD Jack
Specifications
•
Accepts 2 Volts at 50 Kohms maximum input
•
0 –18 dB attenuation
CONTACT
CLOSURE
Adjunct Jack
Specifications
•
Operates up to 150 feet (45.72 meters) from control unit using 24 gauge solid conductor
wire if 2 Contact Closures used; up to 800 feet (243.84 meters) from control unit using 24
gauge solid conductor wire if only 1 Contact Closure used
•
Install the Contact Closure Adjunct in the same building as the control unit; cannot be
installed out-of-doors
•
Has three terminals per Contact Closure, providing a normally open and normally closed
function for each Contact Closure
•
Maximum contact voltages and current:
30 VAC, 1 Amp
50 VDC, 1 Amp
SMDR Output
Format
•
1200 baud
•
8 data bits
•
XON/XOFF protocol
•
Line feeds
•
No parity
•
2 stop bits
•
Carriage return