Procedure 14.1: ACTIVATE FEATURE FOR RECOVERY FROM ALTERNATE BOOT DISK
(UN597)
OVERVIEW
This procedure provides the
5ESS
®
-2000 switch customer with access to the Alternate Boot Disk (ABD) capability in
the event of required system recovery action. The ABD feature enables the customer to select MHDs 14 or 15 as an
alternate boot MHD remotely from the Switching Control Center (SCC) to recover the 5ESS-2000 switch.
In order to activate the ABD feature, the Secured Feature ID must also be actived. The customer is responsible for
contacting the Lucent Regional Engineer who in turn will set the Secured Feature ID to ON.
Prerequisites
The following conditions and requirements must be met before continuing with this procedure.
The Secured Feature ID must be ON.
A
bkup:odd,am
is required after the Secured Feature is set to ON.
The office must be equipped with MHDs 14 and/or 15.
The office must be equipped with a pair of MTTYC UN597 circuit boards.
There should be no system update activity taking place when performing this procedure.
All Administrative Module (AM) hardware should be either active or standby.
The office must be on TNM release NEI 4.2 or 4.3.
The office must be on software release 5E13 or later.
PROCEDURE
14.1.1 Verify Status of Secured Feature ID (SFID)
1.
At the MTTY, to display Recent Change/Verify (RC/V) options, enter Poke command
196
Response:
RC/V Options menu displayed.
2.
Press <CR> key three times.
Response:
RC/V Class Menu displayed.
3.
Type and enter
8.22r
Response:
Secured Feature Form displayed. Cursor at Feature ID.
4.
Type and enter
284
Response:
Cursor at Module Field.
5.
Type and enter
193
235-105-210
October 1999
Copyright © 1999
Page 1
Summary of Contents for 5ESS-2000
Page 96: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 184: ...235 105 210 October 1999 Copyright 1999 Page 3 ...
Page 300: ...13 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 55 ...
Page 339: ...7 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 342: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 359: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 609: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 12 ...
Page 676: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 792: ...3 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 799: ...Figure 11 36 3 1 Cleaning Points 235 105 210 October 1999 Copyright 1999 Page 7 ...
Page 801: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Page 839: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 16 ...
Page 999: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Page 1008: ...Figure 11 55 1 CTSNS DIP Switch Settings 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1011: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1053: ...235 105 210 October 1999 Copyright 1999 Page 15 ...
Page 1289: ...Figure 15 17 2 AMATPS Data Link 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1292: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Page 1303: ...9 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1360: ...Figure 15 47 2 Typical SCANS III Link Diagram 235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1372: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Page 1374: ...235 105 210 October 1999 Copyright 1999 Page 4 ...
Page 1421: ...Table 1 1 O M Checklist 235 105 210 October 1999 Copyright 1999 Page 3 ...