12. Connect the configuration signal cable. See “Power and signal cables for internal drives” on page 182 for
information about cabling the power and signal cables.
13. Complete the cabling of the ServeRAID-BR10i SAS/SATA adapter.
• For the eight drive-bay, 2.5 inch server model, connect one end of the signal cable to the drive
backplane for drive bays 0 through 3 and route the other end through the plastic slot on the bottom
of the chassis underneath the front fan cage; then, connect it to the ServeRAID-BR10i SAS/SATA
controller as shown in the following illustrations:
1
Signal cable for drives 0-3 (backplane labeled A0)
2
Adapter connector for drives 0-3 signal cable
The following illustration shows the connectors on the controller to which you connect the signal
cables from the drive backplanes.
1
ServeRAID-BR10i controller
2
Adapter connector for drives 0-3 signal cable
3
Adapter connector for drives 4-7 signal cable
Connect one end of the other signal cable to the drive backplane for drive bays 4 through 7 and
route the other end of the cable through the plastic slots on the bottom of the chassis underneath
Chapter 7
.
Installing and replacing FRUs
229
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...