Note:
DIMM connectors 1, 4, 9, and 12 are not functional in this server. Do not install DIMMs
in these connectors.
1
DIMM 1 (reserved)
9
DIMM 9 (reserved)
2
DIMM 2
10
DIMM 10
3
DIMM 3
11
DIMM 11
4
DIMM 4 (reserved)
12
DIMM 12 (reserved)
5
DIMM 5
13
DIMM 13
6
DIMM 6
14
DIMM 14
7
DIMM 7
15
DIMM 15
8
DIMM 8
16
DIMM 16
Step 6.
Open the retaining clips on DIMM connector.
Attention:
To avoid breaking the retaining clips or damaging the DIMM connectors, open and
close the clips gently.
Step 7.
Touch the static-protective package that contains the DIMM to any unpainted metal surface on the
server; then, remove the new DIMM from the package.
Step 8.
Turn the DIMM so that the DIMM keys align correctly with the connector.
Chapter 7
.
Installing and replacing FRUs
215