Important:
To ensure that any of your ServeRAID 10i, 10is, or 10M adapters function properly on
UEFI-based servers, make sure that the adapter firmware level is updated to at least 11.xx-XXX, and the
supporting drivers.
Attention:
Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
To install the ServeRAID-MR10i adapter, complete the following steps:
1. Read the safety information (see Chapter 2 “Safety information” on page 3).
2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
Attention:
To avoid breaking the retaining clips or damaging the ServeRAID-MR10i adapter connector,
open and close the clips gently.
3. Remove the side cover (see “Removing the side cover” on page 146).
4. Carefully lay the server on its side so that it is lying flat and facing up.
Note:
Do not allow the server to fall over.
5. Remove the screw that secures the expansion-slot cover to the chassis (if no adapter is installed in the
slot). Store the expansion-slot cover and screw in a safe place for future use.
Note:
Expansion-slot covers must be installed on all vacant slots. This maintains the electronic emissions
standards of the server and ensures proper ventilation of server components.
6. Open the retaining clips on each end of the ServeRAID-MR10i adapter connector on the system board.
7. Touch the static-protective package that contains the ServeRAID-MR10i adapter to any unpainted metal
surface on the server. Then, remove the ServeRAID-MR10i adapter and battery pack from the package.
8. If the battery pack (battery carrier and battery) did not come installed on the ServeRAID adapter, install
the battery pack.
a. Align the battery carrier pins and the connector for the battery carrier with the pin holes and connector
on the ServeRAID adapter; then, lower the battery carrier onto the ServeRAID adapter.
1
ServeRAID adapter
2
Battery carrier
232
ThinkServer TD200 Hardware Maintenance Manual
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...