1
DIMM 9 (reserved)
15
DIMM 2
2
DIMM 10
16
DIMM 1 (reserved)
3
DIMM 11
17
Battery
4
DIMM 12 (reserved)
18
PCI extender card connector
5
DIMM 13
19
Microprocessor 1
6
DIMM 14
20
Microprocessor 2
7
DIMM 15
21
Slot 6, PCI 32 bit/33 MHz
8
DIMM 16
22
Slot 5, PCI Express Gen2 x8 (x8)
9
DIMM 8
23
Slot 4, PCI Express Gen2 x8 (x4)
10
DIMM 7
24
Slot 3, PCI Express Gen2 x8 (x4)
11
DIMM 6
25
Slot 2, PCI Express Gen2 x18 (x8)
12
DIMM 5
26
Slot 1, PCI Express Gen2 x8 (x8)
13
DIMM 4 (reserved)
27
Virtual media key connector
14
DIMM 3
28
Optional VRM connector
To install the microprocessor and heat sink, complete the following steps.
Step 1.
Touch the static-protective package that contains the microprocessor to any unpainted metal
surface on the server. Then, remove the microprocessor from the package.
Step 2.
Install the VRM in the VRM connector:
Chapter 7
.
Installing and replacing FRUs
191
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...