• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 “Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836” on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
Action
0011000
Invalid microprocessor type.
1. Update the server firmware to the latest level (see
“Updating the firmware” on page 306).
2. (Trained service technician only) Remove and
replace the affected microprocessor (error LED
is lit) with a supported type (see “Installing a
microprocessor and heat sink” on page 189).
0011002
Microprocessor mismatch.
1. Run the Setup utility and select
System
Information
®
System Summary
®
Processor
Details
to view the microprocessor information
to compare the installed microprocessor
specifications.
2. (Trained service technician only) Remove and
replace one of the microprocessors so that they
both match.
0011004
Microprocessor failed BIST.
1. Update the server firmware to the latest level (see
“Updating the firmware” on page 306).
2. (Trained service technician only) Reseat
microprocessor 2.
3. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board
001100A
Microcode updated failed.
1. Update the server firmware to the latest level (see
“Updating the firmware” on page 306).
2. (Trained service technician only) Replace the
microprocessor.
0050001
DIMM disabled.
1. If the server fails the POST memory test, reseat the
DIMMs.
2. Remove and replace any DIMM for which the
associated error LED is lit (see “Removing a
memory module” on page 209 and “Installing a
memory module” on page 211).
3. Run the Setup utility to enable all the DIMMs.
4. Run the DSA Preboot memory test (see “Running
the diagnostic programs” on page 70).
Chapter 5
.
Diagnostics
25
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...