Drive tray handle (in open position)
4
Release latch
5
Hard disk drive
Step 5.
Make sure that the tray handle is open.
Step 6.
Align the drive assembly with the guide rails in the bay.
Step 7.
Push the drive into the bay until the drive stops.
Step 8.
Push the tray handle to the closed (locked) position.
Step 9.
Check the hard disk drive status indicator to make sure that the hard disk drive is operating
correctly.
After you replace a failed hard disk drive, the green activity LED flashes as the disk spins up. The
amber LED turns off after approximately 1 minute. If the new drive starts to rebuild, the amber
LED flashes slowly, and the green activity LED remains lit during the rebuild process. If the
amber LED remains lit continuously, the drive is faulty and must be replaced. See Chapter 5
“Diagnostics” on page 21.
Note:
You might have to reconfigure the disk arrays after you install hard disk drives.
Step 10. Close the bezel.
Step 11. Lock the side cover.
Removing a 3.5-inch hot-swap hard disk drive
Attention:
To maintain proper system cooling, do not operate the server for more than 10 minutes without
either a drive or a filler panel installed in each drive bay.
To remove a 3.5-inch hot-swap SAS or hot-swap SATA hard disk drive, complete the following steps.
Step 1.
Read the safety information (see Chapter 2 “Safety information” on page 3).
Step 2.
Unlock the side cover.
Step 3.
Open the bezel. Place your finger on the pull point area on the left side of the bezel door and
rotate it away from the server.
176
ThinkServer TD200 Hardware Maintenance Manual
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...