• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 “Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836” on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
The Processor CPU
n
Status has
Failed with IERR.(
n
= microprocessor
number)
Error
A processor failed - IERR
condition has occurred.
1. Make sure that the latest levels
of firmware and device drivers
are installed for all adapters
and standard devices, such as
Ethernet, SCSI, and SAS.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
2. Run the DSA program for the
hard disk drives and other I/O
devices.
3. (Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
An Over-Temperature Condition has
been detected on the Processor
CPU
n
Status.(
n
= microprocessor
number)
Error
An overtemperature
condition has occurred
for microprocessor
n
.(
n
=
microprocessor number)
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffle is in place and
correctly installed, and that the
server cover is installed and
completely closed.
2. Make sure that the heat sink for
microprocessor
n
is installed
correctly.
3. (Trained service technician
only) Replace microprocessor
n
.
(
n
= microprocessor number)
34
ThinkServer TD200 Hardware Maintenance Manual
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...