Note:
Make sure that all cables are routed so that they are not damaged when inserting the
fan cage assembly into the server.
Step 7.
Install the air baffle (see “Installing the air baffle” on page 251).
Step 8.
Rotate the power-supply cage assembly back into the server. Press the power-supply cage release
tab and rotate the power-supply cage assembly into the chassis.
1
Power supply support bracket
2
Power-supply release tab
Step 9.
Install the side cover (see “Installing the side cover” on page 252).
Step 10. Lock the side cover.
Step 11. Reconnect the external cables and power cords; then, turn on the attached devices and turn on
the server.
Removing the rear adapter-retention bracket
To remove the rear adapter-retention bracket, complete the following steps:
Step 1.
Turn off the server and all attached devices; then, disconnect all power cords and external cables.
Step 2.
Unlock and remove the side cover (see “Removing the side cover” on page 146).
Step 3.
Remove all adapters and place the adapters on static-protective surface (see “Removing an
adapter” on page 217).
Note:
You might find it helpful to note where each adapter is installed before removing the adapters.
Step 4.
Open the rear adapter retention bracket.
Step 5.
Press the rear adapter retention bracket and release the top hinge point; then, release the other
hinge point and remove the bracket from the chassis.
Chapter 7
.
Installing and replacing FRUs
155
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...