6. Press down firmly on the heat sink until it is seated securely.
7. Rotate the heat-sink lever to the closed position and hook it underneath the lock tab.
Step 10. Reinstall the air baffle (see “Installing the air baffle” on page 251).
Step 11. Rotate the power-supply cage assembly back into the server. Press the power-supply cage release
tab and rotate the power-supply cage assembly into the chassis.
1
Power supply support bracket
2
Power supply release tab
If you have other options to install or remove, do so now. Otherwise, go to “Completing the installation” on
page 249.
Removing a ServeRAID-BR10i SAS/SATA controller
To remove a ServeRAID-BR10i SAS/SATA adapter, complete the following steps:
Step 1.
Read the safety information (see Chapter 2 “Safety information” on page 3).
Step 2.
Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
Remove the side cover (see “Removing the side cover” on page 146).
Step 3.
Carefully lay the server on its side so that it is lying flat and facing up.
Note:
Do not allow the server to fall over.
Step 4.
Rotate the rear adapter-retention bracket to the open (unlocked) position.
Step 5.
Disconnect any cables connected to the adapter.
Attention:
To avoid breaking the retaining clips or damaging the ServeRAID-BR10i adapter
connector, open and close the clips gently.
226
ThinkServer TD200 Hardware Maintenance Manual
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...