Table 1. Features and specifications (continued)
Drives (depending on the model):
• Optical drives: SATA
• Hard disk drives: SAS and SATA
Drive bays (depending on the
model):
• Three 5.25-in. bays (one half-high
DVD-ROM drive installed).
Optionally you can install one
full-high or two half-high internal
tape drives in bays 2 and 3.
• One of the following:
– Four 3.5-inch simple-swap
SATA drives
– Four 3.5-inch hot-swap SAS or
SATA drives
– Eight 2.5-inch hot-swap SAS or
SATA drives
Integrated functions:
• Integrated Management Module
(IMM), which provides service
processor control and monitoring
functions, video controller, and
(when the optional virtual media
key is installed) remote keyboard,
video, mouse, and remote hard
disk drive capabilities
• Broadcom BCM5709 Gb Ethernet
controller with TCP/IP Offload
Engine (TOE) and
®
Wake on LAN
support
• Onboard SATA controller
(simple-swap models)
• Seven Universal Serial Bus (USB)
2.0 ports (two front and four rear
of the chassis), and one for the
internal USB tape drive.
• Two Ethernet ports
• One System Management RJ-45
on the rear to connect to a systems
management network. This
system management connector is
dedicated to the IMM functions.
This connector is active with or
without the optional Virtual Media
Key installed.
• One serial port
• Six SATA ports (four through the
iPASS connector for simple-swap
drives and two for the optical
drives)
Acoustical noise emissions:
• Sound power, idling: 5.5 bel
• Sound power, operating: 6.0 bel
Environment:
• Air temperature:
– Server on: 10° to 35°C (50° to
95°F) Altitude: 0 to 915 m (3000
ft)
– Server on: 10° to 32°C (50° to
90°F) Altitude: 0 to 915 m (3000
ft) to 2134 m (7000 ft)
– Server on: 10° to 28°C (50° to
83°F) Altitude: 2134 m (7000 ft)
to 3050 m (10000 ft)
– Server off: 5° to 45°C (41.0° to
113°F)
– Shipping: -40° to 60°C (-40° to
140°F)
• Humidity (operating and storage):
– Server on: 20% to 80%,
Maximum dew point 21°C,
Maximum rate of change
5°C/hr.
– Server off: 8% to 80%,
Maximum dew point 27°C
Heat output:
Approximate heat
output in British thermal units (Btu)
per hour:
• Minimum configuration: 693 Btu
per hour (203 watts)
• Maximum configuration: 2788 Btu
per hour (817 watts)
12
ThinkServer TD200 Hardware Maintenance Manual
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...