• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 “Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836” on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
Action
0058007
DIMM population is unsupported.
1. Reseat the DIMMs, and then restart the server.
2. Remove the lowest-numbered DIMM pair of those
that are identified and replace it with an identical
pair of known good DIMMs, then restart the server.
3. Return the removed DIMMs, one pair at a time, to
their original connectors, restarting the server after
each pair, until a pair fails. Replace the DIMMs in
the failed pair with identical known good DIMMs,
restarting the server after each DIMM is installed.
Replace the failed DIMM. Repeat this step until you
have tested all removed DIMMs.
4. (Trained service technician only) Replace the
system board.
0058008
DIMM failed memory test.
1. Reseat the DIMMs, and then restart the server.
2. Replace the following components one at a time, in
the order shown, then restart the server after each:
a. DIMM
b. (Trained service technician only) System board
00580A1
Invalid DIMM population for mirroring mode
1. If a fault LED is lit, resolve the failure.
2. Install the DIMMs in the correct sequence (see
“Installing a memory module” on page 211).
00580A4
Memory population changed.
Information only. Memory has been added, moved,
or changed.
00580A5
Mirror failover complete
Information only. Memory redundancy has been lost.
Check the event log for uncorrected DIMM failure
events.
0068002
CMOS battery cleared.
1. Reseat the battery.
2. Clear the CMOS memory.
3. Replace the following components one at a time,
in the following order, restarting the server after
each one:
a. Battery
b. (Trained service technician only) System board.
Chapter 5
.
Diagnostics
27
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...