the fan cage assembly; then, connect it to the ServeRAID-BR10i SAS/SATA controller as shown
in the following illustration:
1
Signal cable for drives 4-7 (backplane labeled A1)
2
Adapter connector for drives 4-7 signal cable
3
Signal cable for drives 0-3 (backplane labeled AD)
4
Adapter connector for drives 0-3 signal cable
Connect the single end of the power cable to the
Hard disk drive backplane power connector
(labeled A) on the system board and connect the split end of the power cable to the connectors on the
backplane as shown in the following illustration.
1
Power connector (labeled A)
2
Power cable
3
Backplane power connectors
230
ThinkServer TD200 Hardware Maintenance Manual