• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 “Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836” on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
Action
2011001
PCI-X PERR
1. Reseat all affected adapters.
2. Update the PCI adapter firmware.
3. Remove the adapter.
4. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. Adapter
b. (Trained service technician only) System board
2018001
PCI Express uncorrected or uncorrected error
1. Reseat all affected adapters.
2. Update the PCI adapter firmware.
3. Remove the adapter.
4. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. Adapter
b. (Trained service technician only) System board
2018002
Option ROM resource allocation failure
Informational message that some devices might not
be initialized.
1. If possible, rearrange the order of the adapters
in the PCI slots to change the load order of the
optional-device ROM code.
2. Run the Setup utility, select
Startup Options
, and
change the boot priority to change the load order
of the optional-device ROM code.
3. Run the Setup utility and disable some other
resources, if their functions are not being used, to
make more space available.
a. Select
Startup Options
, then
Planar Ethernet
(PXE/DHCP)
to disable the integrated Ethernet
controller ROM.
b. Select
Advanced Functions
, then
PCI Bus
Control
, then
PCI ROM Control Execution
to
disable the ROM of the adapter in the PCI slots.
c. Select
Devices and I/O Ports
to disable any of
the integrated devices.
4. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. Each adapter
b. (Trained service technician only) System board
28
ThinkServer TD200 Hardware Maintenance Manual
Summary of Contents for ThinkServer TD200
Page 2: ......
Page 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Page 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Page 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Page 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Page 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Page 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Page 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Page 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Page 345: ......
Page 346: ...Part Number Printed in USA 1P P N ...