15. Configuring the Snapshots System
Reset Channel Parameters
When activated, this control signal resets DSP parameters for the source "in access" to their
default values.
Unlock Save & Load
Use these options to protect the SAVE and LOAD buttons on the Central Module.
When nothing is assigned, or the
Enable
box is unticked, the function is always available to
the operator.
To protect the function, assign an input control signal and tick the
Enable
checkbox.
The following control outputs appear in the 'Tree Selection' window under “Logic -> Definition -> Parameter =
Snapshots”:
Snapx.set
Active when data is stored to the internal snapshot memory. This can be used to signal to the
operator which memories contain settings and which memories are empty.
Snapx.load
This output is pulsed when the snapshot is loaded.
Src Clipboard.set
Active when data is stored to the internal clipboard.
Glb Snap loaded pulse
This output is pulsed when a
Full
snapshot is loaded.
Src Snap loaded pulse
This output is pulsed when a
Src