9. Audio IO
9.3.3
Using the RAVENNA Web UI
The RAVENNA Web UI is used for four main tasks:
·
To change the IP settings of the streaming ports.
·
To check the synchronization status of the PTP clock source.
·
To assign audio to the 32 stereo Rx streams.
·
To check the status of the Tx streams.
Note that the latest settings are stored locally on the device, and are re-instated following a power cycle or
reboot.
Any settings changed from the RAVENNA Web UI can be backed up (and restored) using the "Backup &
Restore Config" tool. This is ideal if you need to exchange an IO card or device.
9.3.4
Opening the RAVENNA Web UI
The RAVENNA Web UI can be launched from SoP Explorer as follows:
1.
Select the RAVENNA IO Card and then click on the "run web browser" icon - the Comi.MX Landing
Page appears:
SoP Explorer - opening the Landing Page
Alternatively, open a web browser application and enter the IP address of the connected streaming port into the
URL field. The default IP addresses are:
·
ETHERNET A = 192.168.101.250
·
ETHERNET B = 192.168.110.253