23. Maintenance
23.5.2
Configuring an Alarm Log Server
"Logic -> ALARM"
To support an external Alarm Log Server, you will need to define an
Alarm
element to the "
Logic
" branch of the
'Tree Definition'.
ALARM
Reference name for the element.
Trigger
Assigns the input control signal which will transmit the
Text Rising
and
Text Falling Edge
messages at each status change.
Invert
When checked, the input control signal is inverted.
Text Rising Edge
Enter the text which will be transmitted to the external Alarm Log Server system at the rising
edge of the
Trigger
signal.
Text Falling Edge
Enter the text which will be transmitted to the external Alarm Log Server system at the falling
edge of the
Trigger
signal.
Info
When checked, this output is treated as an ‘Info’ message within the Alarm Log Server
system, as opposed to an ‘Alarm’ message.
Alarm Number
Enter a specific error code which you wish to be transmitted to the external messaging
system.
Unit
The unit number is transferred to the Alarm Log Server. For example, you may set Studio 1
as Unit 1, etc.
Address
This is an Address transferred to the Alarm Log Server. For example, you may use this to
identify different system addresses.