crystal User Manual
Version: 6.6.0/2
386/459
20. Networking Options
GPI/O Network Configuration
Next, to transfer the “Mic Arbitration” control data, you must configure a
and each of the client systems. Note that the “Mic Arbitration” data is transmitted transparently. In other words,
it does not use up any of the 32 configurable GPIOs or 10 level controls.
1.
Within the first client, select the
GPI/O Network
branch of the 'Tree Definition' and Insert a
Net
element in the usual manner.
2.
Name the GPI/O Network Port in the
Net
box (e.g.
Studio 1<->Nova17
) and enter the Port number (
1
):
If Port
1
is already in use (for a different application), you should choose the next available port number.
3.
Repeat for the second client, this time entering a different Port number (
2
):
4.
Now open the server's configuration and add two GPI/O Network
Net
elements.
5.
Enter Port number
1
for the connection to Studio 1 and Port number
2
for the connection to Studio 2:
You can use the
Mic Arb Offset
field to apply an offset to the
client). Apply this to each GNET port within the server so that the mic arbitration input numbers for different
consoles are discrete.