crystal User Manual
Version: 6.6.0/2
399/459
20. Networking Options
20.4.4
V__line Devices
The
Ember+ V_pro8 GPI
element can be used to control presets within a Lawo V__pro8. Any one of four
V_pro8 presets (A to D) can be triggered from 8 GPIs. Note that the V__pro8 must be running Version 1.1.7.24
software or later.
There are two parts to the configuration. First, define the system to be an
(in the "System ->
Definition -> Parameter = Local Consumers"). Then define an
Ember+ V_pro8 GPI
element as described
below.
Global Parameters
EmBER+ V_pro8 GPI
Reference name for the element.
V_pro8 Nr
Assign a number to the V_pro8 unit (from 1 to 5). This number must be unique.
Local Consumer Nr
you wish to use (as defined under “System -> Definition -
> Parameter = Local Consumers”).
GPI Parameters
Select this tab to define the GPIs and presets:
GPI x Setting
Defines which preset (A to D) will be recalled when the
GPI Trigger
signal is true.
GPI x Trigger
Assigns an input control signal to trigger the GPI.