Master Mode
Master Mode Page 1
11-3
Digital Output
This Digital Output parameter specifies the PC3's digital output sample rate. Internally clocked
sample rates go from 44.1K up to 192K.
Externally synced sample rates cover 20-220KHz in 3 ranges. Be sure the external clock
frequency is within the range you select.
Aux Out Pair Mode
The Aux Out Pair Mode parameter specifies the behavior of the Secondary Audio Outputs
(located on the back panel underneath the “Balanced Analog Outputs - AUX” label. Setting this
parameter to
Normal
makes the Aux Outputs behave as such. Setting this parameter to
Mirror
Primary Outputs
makes the Aux Outputs output the same audio signal as the Primary output.
Tempo
When Clock Source is set to
Internal
, the Tempo parameter sets the PC3 system’s tempo. The
Tempo parameter values are in units of bpm (beats per minute).
Clock Source
With the Clock Source parameter, you can set the PC3 to generate its own tempo by setting
Clock Source to
Internal
, or you can set the PC3 to sync up with the tempo from another
device—assuming the device is sending MIDI clock data to the PC3 via MIDI or USB—by
setting Clock Source to
External
.
Output Clock
To send a MIDI clock pulse through of the MIDI Out port, set this parameter to
On
. Otherwise,
set it to
Off
.
Digital Output Volume
The Digital Output Volume parameter specifies the behavior of the PC3’s Digital Output. Setting
this parameter to
Variable
makes the Digital Output respond to changes made on the volume
slider. Setting this parameter to
Fixed
makes the Digital Output output a signal with a fixed
volume.
Summary of Contents for PC3
Page 24: ...1 6 Introduction Options ...
Page 50: ...4 4 The Operating Modes Using the Modes ...
Page 174: ...7 54 Setup Mode The Utility Soft Buttons ...
Page 178: ...8 4 Quick Access Mode Making Your Own QA Banks ...
Page 204: ...9 26 Effects Mono Algorithms ...
Page 266: ...A 2 MIDI Implementation Chart ...
Page 308: ...Index x ...