90
5.2 Exposure procedure with DR Detector (Basic connection)
5 .2 .5 Exposure procedure
The exposure procedure is as follows:
This section shows an example case of exposing sev
-
eral body parts under the following conditions .
Exposure device
• Wall stand × 1
• DR Detector × 1
* Assume that the wall stand uses the AeroDR
UF Cable, and the DR Detector is inserted into
the AeroDR Battery Charger .
Exposure conditions and order of exposure
(1) CHEST - Chest Erect - AP
(2) SPINE - L-Spine - AP
(3) HEAD - Skull - PA
The exposure sequence and the positions in which
exposure images are displayed are as shown be
-
low .
(1)
(3)
(2)
CHEST - Chest
Erect - AP
HEAD - Skull -
PA
SPINE - L-Spine
- AP
* The exposure sequence (1) - (3) is displayed for
ease of explanation, and is not displayed on the
actual screen .
IMPORTANT
•••••••••••••••••••••••••••••••••••••
•
Always check the patient information and exposure
conditions before exposure.
• The DR Detector is precision equipment, and there-
fore impact or vibration during radiography or image
transfer may affect the image quality. Be careful when
handling the DR Detector during and just after radiog-
raphy .
•
If an image is displayed when an exposure is not per
-
formed, this may be a detection error due to noises,
etc . Perform rejected image (deletion of images) and
repeat exposure.
•
If you have performed an exposure when "Ready" was
not displayed, repeat an exposure after approximately
one minute .
•
The selected Exam. Tag is added to the Exam.
Tags display area . By repeating from step 1,
Exam. Tags can be added.
4
When finished selecting/adding the Exam.
Tags, press [Perform] .
•
The exposure screen is displayed.
HINT
•••••••••••••••••••••••••••••••••••••
•
When only reserving an examination, after adding the
Exam. Tag, press [Schedule]. After reservation is per
-
formed, the initial screen is displayed .
•
Returning to the initial screen by pressing [Schedule]
does not set study date and time of image supplemen-
tal information automatically .
•
It is also possible to register multiple exposure methods
in 1 Exam. Tag. Register these methods when install
-
ing .
•
If you have set to register the Exam. Tags automati
-
cally, the body part selection screen is not displayed .
The display transitions to the exposure screen.
•••••••••••••••••••••••••••••••••••••••••••••••••••••
Summary of Contents for CS-7
Page 1: ...0197 Operation Manual EN 15 DIRECT DIGITIZER Version 1 30 ...
Page 2: ......
Page 8: ...8 ...
Page 9: ...9 Introduction ...
Page 18: ...18 ...
Page 30: ...30 ...
Page 31: ...31 Chapter 2 Product Overview This chapter describes the overview of this device ...
Page 34: ...34 ...
Page 74: ...74 ...
Page 84: ...84 ...
Page 120: ...120 ...
Page 197: ...197 Chapter 7 Various Functions This chapter describes the functions of this device ...
Page 383: ...383 Chapter 10 Error Codes This chapter describes the error codes and countermeasures ...
Page 413: ...413 Chapter 11 Maintenance This chapter describes the items that require periodic maintenance ...
Page 416: ...416 ...
Page 417: ...417 Chapter 12 Specifications This chapter describes the specifications of this device ...
Page 422: ...422 ...
Page 423: ......
Page 424: ...A47FBA01EN15 2017 01 12 JD ...