![Kentrox RMM-1400 Configuration Manual Download Page 133](http://html1.mh-extra.com/html/kentrox/rmm-1400/rmm-1400_configuration-manual_1955455133.webp)
Remote RMM-1400 Version 2.0x Configuration Guide
Configuring Mediation Connections: Configuring an Asynchronous Serial to Asynchronous Serial
Connection
14-11
5. (optional) At the main prompt, configure controller
serial 1
with application
mode
destination
:
config controller serial 1 application destination
Note:
By default, asynchronous serial controllers are configured to act as both
sources and destinations for connections, which makes configuration of
this command optional.
6. (optional) Configure connection mode
activity
:
config controller serial 1 connect mode activity
7. Configure controller
serial 2
application mode as
source
:
config controller serial 2 application source
8. Configure connection mode
dcd
:
config controller serial 2 connect mode dcd
9. (optional) Verify that the serial controllers have been configured properly:
show controllers serial 1
The command response appears similar to the following:
(Dub)>show controllers serial 1
serial 1 status=enabled link-state=down encapsulation= baud=9600 databits=8
stopbits=1 parity=none resource-state=unassigned
flow-control=none
linemode=rs232
dial-timer=1
init-string=
connect-mode= activity
rts-connect-mode=on
dtr-connect-mode=on
disconnect-mode=
rts-disconnect-mode=off
dtr-disconnect-mode=off
parity-errors=0
description=Asynchronous port
application=destination
(Dub)>