Problems Transmitting Data Through the DCS 300
If you have a problem while running the application on the 2461 terminal in a UDP
Plus network, check these possible communications problems.
Problem
Solution
Transaction Buffer Full.
The buffer holding transactions to be sent to the controller is full. Stop
collecting data with this terminal. Make sure the terminal is
communicating with the DCS 300 and let the terminal send all the
transactions in the buffer before you continue collecting data.
Sending Buffer Transactions.
This is an information message to tell you that buffered transactions are
now being sent to the DCS 300. You can begin collecting data again
once the message clears.
Transaction Aborted.
The transaction just sent to the DCS 300 was not received. Try sending
the transaction again.
Transmit Error XX, press Enter.
There is an error transmitting data to the DCS 300. XX represents the
status code error. Note the error code listed in the message and contact
your local Intermec service representative for help. Press
W to
continue.
Receive Error XX, press Enter.
There is an error receiving data from the DCS 300. XX represents the
status code error. Note the error code listed in the message and contact
your local Intermec service representative for help. Press
W to
continue.
Shutting down.
The DCS 300 is shutting down. You may continue collecting data and
buffer the transactions in the terminal until the DCS 300 starts again, or
stop collecting data with the terminal.
Controller Shutdown.
The DCS 300 has shut down. You may continue collecting data and
buffer the transactions in the terminal until the DCS 300 starts again, or
stop collecting data with the terminal.
Summary of Contents for Trakker Antares 2460
Page 1: ...Trakker Antares 246X Stationary Terminal User s Manual...
Page 4: ...blank page...
Page 19: ...Introducing the 246X Stationary Terminal 1...
Page 20: ...blank page...
Page 29: ...Installing the Terminal 2...
Page 30: ...blank page...
Page 47: ...Configuring the Terminal 3...
Page 48: ...blank page...
Page 58: ...blank page...
Page 59: ...Operating the Terminal in a Network 4...
Page 60: ...blank page...
Page 88: ...blank page...
Page 89: ...Programming the Terminal 5...
Page 90: ...blank page...
Page 107: ...Troubleshooting 6...
Page 108: ...blank page...
Page 121: ...Reader Command Reference 7...
Page 122: ...blank page...
Page 149: ...Configuration Command Reference 8...
Page 150: ...blank page blank page...
Page 242: ...blank page blank page...
Page 243: ...Specifications A...
Page 244: ...blank page blank page...
Page 257: ...Full ASCII Charts B...
Page 258: ...blank page blank page...
Page 267: ...Using the Default Applications C...
Page 268: ...blank page blank page...
Page 279: ...Index I...
Page 280: ...blank page...
Page 290: ...body text 4...